3 Wiring and Connection

3.4.1 Reference Input Circuit

3-34

• Precaution when host controller uses open collectors with customer-supplied power.

Before wiring, confirm that the specifications of the host controller satisfy the values
shown in the following table.
If these conditions are not satisfied, the SERVOPACK may malfunction.

Pull-up voltage (Vcc)

Pull-up resistance (R1)

24 V

1.8 to 2.7 k

Ω

12 V or less

820

Ω to 1.5 kΩ

5 V or less

180 to 470

Ω

Circuit example of open-controller output

SERVOPACK

VF = 1.5 to 1.8 V

Vcc

Tr1

VF

R1

i

Host controller

150

Ω

4.7 k

Ω

Pull-up