10.1 Alarm Displays

10-13

10

Trou

blesh

ooting

A.810:
Encoder Backup Error
(Only when an absolute

encoder is connected.)
(Detected on the encoder

side.)

Alarm occurred when the power

to the absolute encoder was ini-

tially turned ON.

Check to see if the power was

turned ON initially.

Set up the encoder (Fn008).

The encoder cable disconnected,

and connected again.

Check to see if the power was

turned ON initially.

Confirm the connection and set up

the encoder (Fn008).

The power from both the control

power supply (+5 V) from the

SERVOPACK and the battery

power supply is not being sup-

plied.

Check the encoder connector bat-

tery or the connector contact status.

Replace the battery or take similar

measures to supply power to the

encoder, and set up the encoder

(Fn008).

An absolute encoder fault

occurred.

If the alarm cannot be reset by set-

ting up the encoder again, replace

the servomotor.

A SERVOPACK fault occurred.

The SERVOPACK may be faulty.

Replace the SERVOPACK.

A.820:
Encoder Checksum

Error
(Detected on the encoder

side.)

An encoder fault occurred.

• Absolute encoder

Set up the encoder again using
Fn008. If the alarm still occurs,

the servomotor may be faulty.
Replace the servomotor.

• Absolute encoder that shows val-

ues for a single rotation or incre-
mental encoder
The servomotor may be faulty.
Replace the servomotor.

A SERVOPACK fault occurred.

The SERVOPACK may be faulty.

Replace the SERVOPACK.

A.830:
Absolute Encoder Bat-

tery Error
(The absolute encoder

battery voltage is lower

than the specified value.)

The battery connection is incor-

rect.

Check the battery connection.

Reconnect the battery.

The battery voltage is lower than

the specified value 2.7 V.

Measure the battery voltage.

Replace the battery.

A SERVOPACK fault occurred.

The SERVOPACK may be faulty.

Replace the SERVOPACK.

A.840:
Encoder Data Error
(Detected on the encoder
side.)

An encoder malfunctioned.

Turn the power supply OFF and

then ON again. If the alarm still

occurs, the servomotor may be

faulty. Replace the servomotor.

Malfunction of encoder because

of noise interference, etc.

Correct the wiring around the

encoder by separating the encoder

cable from the servomotor main cir-

cuit cable or by checking the

grounding and other wiring.

A.850:
Encoder Overspeed
(Detected when the con-

trol power supply was

turned ON.)
(Detected on the encoder

side.)

The servomotor speed is higher
than 200 min

-1

when the control

power supply was turned ON.

Check the motor rotating speed

(Un000) to confirm the servomotor

speed when the power is turned ON.

Reduce the servomotor speed to a
value less than 200 min

-1

, and turn

ON the control power supply.

An encoder fault occurred.

Turn the power supply OFF and

then ON again. If the alarm still

occurs, the servomotor may be

faulty. Replace the servomotor.

A SERVOPACK fault occurred.

Turn the power supply OFF and

then ON again. If the alarm still

occurs, the SERVOPACK may be

faulty. Replace the SERVOPACK.

(cont’d)

Alarm Number:

Alarm Name

(Alarm Description)

Cause

Investigative Actions

Corrective Actions

Advertising