2 sequence input circuit, 1) photocoupler input circuit – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual

Page 86

Advertising
background image

3.4 Examples of Connection to Host Controller

3-35

3

Wi

ring an

d Conn

ecti

on

3.4.2 Sequence Input Circuit

(1) Photocoupler Input Circuit

CN1 connector terminals 40 to 47 are explained below.

The sequence input circuit interface is connected through a relay or open-collector transistor circuit. When

connecting through a relay, use a low-current relay. If a low-current relay is not used, a faulty contact may
result.

Note: The 24 VDC external power supply capacity must be 50 mA minimum.

For SEN input signal circuit, refer to 5.9.2 Absolute Data Request Signal (SEN).

The SERVOPACK’s input circuit uses bidirectional photocoupler. Select either the sink circuit or the source

circuit according to the specifications required for each machine.

Note:

The connection examples in 3.2.3 to 3.2.5 show sink circuits.

• The ON/OFF polarity differs between when a sink circuit is connected and when a source circuit is connected.

Relay Circuit Example

Open-collector Circuit Example

Sink Circuit

Source Circuit

Input Signal Polarities

Input Signal Polarities

Signal

Level

Voltage

Level

Contact

Signal

Level

Voltage

Level

Contact

ON

Low (L)

level

0 V

Close

ON

High (H)

level

24 V

Close

OFF

High (H)

level

24 V

Open

OFF

Low (L)

level

0 V

Open

3.3 k

Ω

/S-ON, etc.

SERVOPACK

24 VDC

+24 VIN

24 VDC

3.3 k

Ω

/S-ON, etc.

SERVOPACK

+24 VIN

24 V

+

SERVOPACK input

24 V

+

SERVOPACK input

Advertising