Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual

Page 172

Advertising
background image

5 Operation

5.7.2 Switching Other Than Internal Set Speed Control (Pn000.1 = 7, 8 or 9)

5-58

5.7.2 Switching Other Than Internal Set Speed Control (Pn000.1 = 7, 8 or 9)

Use the following signals to switch control methods when Pn000.1 is set to 7, 8, or 9. The control methods

switch depending on the signal status as shown below.

(1) Factory-set Input Signal Allocations (Pn50A.0 = 0)

(2) Changing Input Signal Allocations (Pn50A.0 = 1)

5.7.3 Switching Other Than Internal Set Speed Control (Pn000.1 = A or B)

Use the following signals to switch control methods when Pn000.1 is set to A or B. The control methods

switch depending on the signal status as shown below.

(1) Factory-set Input Signal Allocations (Pn50A.0 = 0)

(2) Changing Input Signal Allocations for Each Signal (Pn50A.0 = 1)

Type

Signal

Name

Connector

Pin Number

Setting

Pn000.1 Setting and Control Method

n.

7

n.

8

n.

9

Input /P-CON

CN1-41

ON (closed)

Speed

Torque

Speed

OFF (open)

Position

Position

Torque

Type

Signal

Name

Connector

Pin Number

Setting

Pn000.1 Setting and Control Method

n.

7

n.

8

n.

9

Input /C-SEL

Must be
allocated

ON (closed)

Speed

Torque

Speed

OFF (open)

Position

Position

Torque

Type

Signal

Name

Connector

Pin Number

Setting

Pn000.1 Setting and Control Method

n.

A

n.

B

Input /P-CON

CN1-41

ON (closed)

Speed control with
zero clamp function

Position control with
reference pulse
inhibit function

OFF (open)

Speed

Position

Type

Signal

Name

Connector

Pin Number

Setting

Pn000.1 Setting and Control Method

n.

A

n.

B

Input

/ZCLAMP

Must be
allocated

ON (closed)

Speed control with
zero clamp function

OFF (open)

Speed

/INHIBIT

ON (closed)

Position control with
reference pulse
inhibit function

OFF (open)

Position