Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual

Page 351

Advertising
background image

10 Troubleshooting

10.1.1 List of Alarms

10-4

A.8A3

External Encoder Error of

Position

The position data of external encoder is

faulty.

Gr.1

Available

H

H

H

A.8A5

External Encoder

Overspeed

The overspeed from the external encoder
occurred.

Gr.1

Available

A.8A6

External Encoder

Overheated

The overheat from the external encoder
occurred.

Gr.1

Available

A.A

*1

SERVOPACK: Command

Option Module Alarms

A.b10

Speed Reference A/D

Error

The A/D converter for speed reference input
is faulty.

Gr.2

Available

H

H

H

A.b11

Speed Reference A/D

Data Error

A/D conversion data of speed reference
input is incorrect.

Gr.2

Available

A.b20

Reference Torque Input

Read Error

The A/D converter for torque reference
input is faulty.

Gr.2

Available

A.b31

Current Detection Error 1

The current detection circuit for phase U is
faulty.

Gr.1

N/A

A.b32

Current Detection Error 2

The current detection circuit for phase V is
faulty.

Gr.1

N/A

A.b33

Current Detection Error 3

The detection circuit for the current is
faulty.

Gr.1

N/A

A.bF0

System Alarm 0

"Internal program error 0" of the SERVO-
PACK occurred.

Gr.1

N/A

A.bF1

System Alarm 1

"Internal program error 1" of the SERVO-
PACK occurred.

Gr.1

N/A

A.bF2

System Alarm 2

"Internal program error 2" of the SERVO-
PACK occurred.

Gr.1

N/A

A.bF3

System Alarm 3

"Internal program error 3" of the SERVO-
PACK occurred.

Gr.1

N/A

A.bF4

System Alarm 4

"Internal program error 4" of the SERVO-
PACK occurred.

Gr.1

N/A

A.C10

Servo Overrun Detected

The servomotor ran out of control.

Gr.1

Available

L

H

L

A.C80

Absolute Encoder Clear

Error and Multiturn Limit

Setting Error

The multiturn for the absolute encoder was
not properly cleared or set.

Gr.1

N/A

A.C90

Encoder Communications

Error

Communications between the SERVO-
PACK and the encoder is not possible.

Gr.1

N/A

A.C91

Encoder Communications

Position Data Error

An encoder position data calculation error
occurred.

Gr.1

N/A

A.C92

Encoder Communications

Timer Error

An error occurs in the communications
timer between the encoder and the SERVO-
PACK.

Gr.1

N/A

A.CA0

Encoder Parameter Error

Encoder parameters are faulty.

Gr.1

N/A

A.Cb0

Encoder Echoback Error

Contents of communications with encoder
are incorrect.

Gr.1

N/A

A.CC0

Multiturn Limit

Disagreement

Different multiturn limits have been set in
the encoder and the SERVOPACK.

Gr.1

N/A

A.CF1

Feedback Option Module

Communications Error

(Reception error)

Reception from the Feedback Option Mod-
ule is faulty.

Gr.1

N/A

A.CF2

Feedback Option Module

Communications Error

(Timer stop)

Timer for communications with the Feed-
back Option Module is faulty.

Gr.1

N/A

(cont’d)

Alarm

Number

Alarm Name

Meaning

Servo-

motor

Stop-

ping

Method

Alarm

Reset

Alarm Code Output

ALO1 ALO2 ALO3

Advertising