6.2 Tuning-less Function

6-17

6

Adjustm

e

nts

(5) Parameters Disabled by Tuning-less Function

When the tuning-less function is enabled in the factory settings, the settings of these parameters are not avail-

able: Pn100, Pn101, Pn102, Pn103, Pn104, Pn105, Pn106, Pn160, Pn139, and Pn408. These gain-related
parameters, however, may become effective depending on the executing conditions of the functions specified

in the following table. For example, if EasyFFT is executed when the tuning-less function is enabled, the set-

tings in Pn100, Pn104, Pn101, Pn105, Pn102, Pn106, and Pn103, as well as the manual gain switch setting,
will be enabled, but the settings in Pn408.3, Pn160.0, and Pn139.0 will be not enabled

.

: Parameter enabled

×

: Parameter disabled

(6) Tuning-less Function Type

The following table shows the types of tuning-less functions for the version of SERVOPACK software.

∗ The software version number of your SERVOPACK can be checked with Fn012.

Parameters Disabled by Tuning-less Function

Related Functions and Parameters*

Item

Name

Pn Number

Torque Con-

trol

Easy

FFT

Mechanical

Analysis (Ver-

tical Axis

Mode)

Gain

Speed Loop Gain
2nd Speed Loop Gain

Pn100
Pn104

Speed Loop Integral Time Constant

Pn101

×

2nd Speed Loop Integral Time Constant

Pn105

Position Loop Gain
2nd Position Loop Gain

Pn102
Pn106

×

Moment of Inertia Ratio

Pn103

Advanced

Control

Friction Compensation Function Selec-

tion

Pn408.3

×

×

×

Anti-resonance Control Adjustment
Selection

Pn160.0

×

×

×

Gain Switch-

ing

Gain Switching Selection Switch

Pn139.0

×

×

×

Software Version*

Tuning-less Type

Meaning

000A or earlier

Tuning-less type 1

000B or later

Tuning-less type 2

The level of noise produced is lower than that of Type 1.

Parameter

Meaning

When Enabled Classification

Pn14F

n.

0

Tuning-less type 1

After restart

Tuning

n.

1

[Factory setting]

Tuning-less type 2

Advertising