5.10 Other Output Signals

5-79

5

Ope

rat

ion

5.10 Other Output Signals

This section explains other output signals.

Use these signals according to the application needs, e.g., for machine protection.

5.10.1 Servo Alarm Output Signal (ALM) and Alarm Code Output Signals (ALO1,

ALO2, and ALO3)

This section describes signals that are output when the SERVOPACK detects errors and resetting methods.

(1) Servo Alarm Output Signal (ALM)

This signal is output when the SERVOPACK detects an error.

(2) Alarm Code Output Signals (ALO1, ALO2, and ALO3)

The ON/OFF combination of these signals specifies the type of alarm detected by the SERVOPACK.

Use these signals as required to display the contents of the alarm at the host controller.

For details, refer to 10.1.1 List of Alarms.

Configure an external circuit so that this alarm output turns OFF the main circuit power
supply for the SERVOPACK whenever an error occurs.

Type

Signal

Name

Connector

Pin Number

Setting

Meaning

Output

ALM

CN1-31, 32

ON (closed)

Normal SERVOPACK status

OFF (open)

SERVOPACK alarm status

Type

Signal Name

Connector

Pin Number

Meaning

Output

ALO1

CN1-37

Alarm code output

ALO2

CN1-38

Alarm code output

ALO3

CN1-39

Alarm code output

SG

CN1-1

Signal ground for alarm code output