Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual

Page 392

Advertising
background image

11 Appendix

11.2.2 Parameters

11-16

Pn010

2

Axis Address Selection (for
UART/USB communications)

0000 to 007F

0001

After restart

Setup

Pn081

2

Application Function Select
Switch 81

0000 to 1111

0000

After restart

Setup

9.1.5

Pn100

2

Speed Loop Gain

10 to 20000

0.1 Hz

400

Immediately

Tuning

6.8.1

Pn101

2

Speed Loop Integral Time
Constant

15 to 51200

0.01 ms

2000

Immediately

Tuning

Pn102

2

Position Loop Gain

10 to 20000

0.1/s

400

Immediately

Tuning

Pn103

2

Moment of Inertia Ratio

0 to 20000

1%

100

Immediately

Tuning

Pn104

2

2nd Speed Loop Gain

10 to 20000

0.1 Hz

400

Immediately

Tuning

Pn105

2

2nd Speed Loop Integral Time
Constant

15 to 51200

0.01 ms

2000

Immediately

Tuning

Pn106

2

2nd Position Loop Gain

10 to 20000

0.1/s

400

Immediately

Tuning

Pn109

2

Feedforward Gain

0 to 100

1%

0

Immediately

Tuning

6.9.1

Pn10A

2

Feedforward Filter Time
Constant

0 to 6400

0.01 ms

0

Immediately

Tuning

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification

Reference

Section

Reserved (Do not change.)

n.

Reserved (Do not change.)

0

1

Phase-C Pulse Output Selection

Outputs phase-C pulse only in forward direction.

Outputs phase-C pulse in forward and reverse direction.

Reserved (Do not change.)

4th
digit

3rd
digit

2nd
digit

1st
digit

Advertising