3) related parameters – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual

Page 316

Advertising
background image

7.22 Online Vibration Monitor (Fn207)

7-39

7

Util

ity Fu

nctions (Fn

)

(3) Related Parameters

The following table lists parameters related to this function and their possibility of being changed while exe-

cuting this function or of being changed automatically after executing this function.

• Parameters related to this function

These are parameters that are used or referenced when executing this function.

• Allowed changes during execution of this function

Yes : Parameters can be changed using SigmaWin+ while this function is being executed.

No : Parameters cannot be changed using SigmaWin+ while this function is being executed.

• Automatic changes after execution of this function

Yes : Parameter set values are automatically set or adjusted after execution of this function.

No : Parameter set values are not automatically set or adjusted after execution of this function.

Parameter

Name

Mid-execution

changes

Automatic

changes

Pn401

Torque Reference Filter Time Constant

No

Yes

Pn408

Torque Related Function Switch

Yes

Yes

Pn409

1st Notch Filter Frequency

No

Yes

Pn40A

1st Notch Filter Q Value

No

No

Pn40C

2nd Notch Filter Frequency

No

No

Pn40D

2nd Notch Filter Q Value

No

No