1.3 SERVOPACK Ratings and Specifications

1-7

1

Outline

∗1. Speed regulation by load regulation is defined as follows:

∗2. Refer to 1.3.1 Ratings for details on regenerative resistors.

∗3. Perform risk assessment for the system and be sure that the safety requirements are fulfilled.

Dynamic Brake (DB)

Activated when a servo alarm or overtravelling occurs or when the power
supply for the main circuit or servomotor is OFF.

Regenerative Processing

Included

*2

Overtravel Prevention (OT)

Dynamic brake stop, deceleration to a stop, or free run to a stop at P-OT or
N-OT

Protective Function

Overcurrent, overvoltage, insufficient voltage, overload, regeneration error,
and so on.

Utility Function

Gain adjustment, alarm history, JOG operation, origin search, and so on.

Safety Function

Input

/HWBB1, /HWBB2: Baseblock signal for power module

Output

EDM1: Monitoring status of internal safety circuit (fixed output)

Standards

*3

EN954 Category 3, IEC61508 SIL2

Option Module

Fully-closed module, safety module

(cont’d)

Speed regulation

=

No-load motor speed

Total load motor speed

Rated motor speed

× 100%

-

Rotation