13 servomotor model display (fn011), 1) preparation, 2) operating procedure – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual

Page 299

Advertising
background image

7 Utility Functions (Fn

)

7-22

7.13 Servomotor Model Display (Fn011)

This function is used to check the servomotor model, voltage, capacity, encoder type, and encoder resolution.

If the SERVOPACK has been custom-made, you can also check the specification codes of SERVOPACKs.

(1) Preparation

There are no tasks that must be performed before the execution.

(2) Operating Procedure

Use the following procedure.

Step

Display after Opera-

tion

Keys

Operation

1

Press the MODE/SET Key to select the utility function.

2

Press the UP or DOWN Key to select Fn011.

3

Press the DATA/SHIFT Key for approximately one second
to display the servomotor voltage and model codes.

4

Press the MODE/SET Key to display the servomotor capac-
ity.

5

Press the MODE/SET Key to display the encoder type and
resolution codes.

∗ The absolute encoder that shows values for a single rota-

tion can only be used with a direct drive motor.

MODE/SET

DATA/

MODE/SET

DATA/

MODE/SET

DATA/

Servomotor Voltage

Code

Type

200 VAC

01

400 VAC

02

Servomotor Model

Code

Model

SGMAV
SGMSV
SGMGV
SGMJV
SGMPS
SGMCS-

C

SGMCS-

D

SGMCS-

B

SGMCS-

E

SGMCS-

L

SGMCS-

M

60
62
63
6D
21
32
33
34
35
36
37

MODE/SET

DATA/

Servomotor capacity in units of 10 W
The above example indicates 100 W.

MODE/SET

DATA/

Encoder Type

Code

Type

Incremental

00

Multiturn
absolute value

01

02

Encoder Resolution

Code

Resolution

13-bit

13

17-bit
20-bit

17
20

Absolute

value
per rotation*