5 monitoring output signals, 1 displaying output signal status – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual
Page 323

8.5 Monitoring Output Signals
8-7
8
Moni
to
r Disp
lays (Un
)
8.5 Monitoring Output Signals
The status of output signals can be checked with the output signal monitor (Un006). The procedure for dis-
playing the status, the method of interpreting the display, and a display example are shown below.
8.5.1 Displaying Output Signal Status
Use the following steps to display the output signal status.
Step
Display after Opera-
tion
Keys
Operation
1
Press the MODE/SET Key to select the monitor display.
2
Press the UP or DOWN Key to select Un006.
3
Output signal display
status
The present status can be displayed on the 7-segment dis-
play on the panel operator by pressing the DATA/SHIFT
Key for approximately one second. Refer to 8.5.2 Interpret-
ing Output Signal Display Status.
4
Press the DATA/SHIFT Key for approximately one second
to return to the display of step 2.
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/