3  Programming the Analyzer

STATus Subsystem

Preset

32767

Min

0

Max

32767

Status Bits/OPC
dependencies

Sequential command

Initial S/W
Revision

Prior to A.02.00

Questionable Frequency Register

The following commands and queries are available for this register:

"Questionable Frequency Condition" on page 157

"Questionable Frequency Enable" on page 157

"Questionable Frequency Event Query" on page 158

"Questionable Frequency Negative Transition" on page 158

"Questionable Frequency Positive Transition" on page 159

Questionable Frequency Condition

This query returns the decimal value of the sum of the bits in the Questionable Frequency
Condition register.

The data in this register is continuously updated and reflects the current conditions.

Mode

All

Remote Command

:STATus:QUEStionable:FREQuency:CONDition?

Example

STAT:QUES:FREQ:COND?

Preset

0

Status Bits/OPC dependencies

Sequential command

Initial S/W Revision

Prior to A.02.00

Questionable Frequency Enable

This command determines which bits in the Questionable Frequency Condition Register will set
bits in the Questionable Frequency Event register, which also sets the Frequency Summary bit (bit