6  RLC Swept SA Measurement Front-Panel & SCPI Reference
Marker To

Mkr->Stop

Changes the stop frequency to the frequency of the selected marker. The marker stays at this
frequency, so it moves to the right edge of the display. In delta marker mode, this function sets
the stop frequency to the x-axis value of the delta marker.

If the currently selected marker is not on when this key is pressed, it will be turned on at the
center of the screen as a normal type marker.

Key Path

Marker ->

Remote Command

:CALCulate:MARKer[1]|2|...12[:SET]:STOP

Example

CALC:MARK3:STOP sets the stop frequency to the value (or delta value) of marker 3.

Notes

Sending this command selects the subopcoded marker

If specified marker is off, this command will turn it on at the center of the screen as a normal
type marker.

Dependencies

This function is not available (key is grayed out) when x-axis is the time domain

Couplings

All the usual couplings associated with setting Stop Frequency apply.

Initial S/W Revision

Prior to A.02.00

Mkr->Ref Lvl

Sets the reference level to the amplitude value of the selected marker, moving the marked point to
the reference level (top line of the graticule). The marker’s mode (Normal, Delta, Fixed) doesn’t
matter in this case. For example, given a delta marker, if the delta marker is the selected marker,
its amplitude is applied to the reference level. If the reference marker is selected, its amplitude is
applied to the reference level.

If the currently selected marker is not on when this key is pressed, it will be turned on at the
center of the screen as a normal type marker, and its amplitude applied to the reference level.

Key Path

Marker ->

Remote Command

:CALCulate:MARKer[1]|2|...12[:SET]:RLEVel

Example

CALC:MARK2:RLEV sets the reference level of the analyzer to the amplitude of marker 2.

Notes

Sending this command selects the subopcoded marker

If specified marker is off, this command will turn it on at the center of the screen as a normal
type marker.

Couplings

All the usual couplings associated with setting Reference Level apply.  

Backwards Compatibility
Notes

Mkr-> RefLvl behavior for a delta marker is slightly different from earlier models. ESA would
calculate the delta amplitude (difference between reference marker and delta marker in dB) and