Configuration

7-14

48XX/49XXSHB0399

7.1.3

Adaptation and adjustment fo the control circuit parameters

7.1.3.1

Adaptation of the armature time constant

If the armature time constant set under C084 (T

SR

) is not the same as the effective

time constant of the motor (T

armature

) (see chapter 5.2), the following occurs:

C084

Effect

Remedy

T

SR

> T

armature

Overcurrents in the armature
possible, the semi-conductor
fuses may trip.

Reduction of C084:

l

Jump signal to the current controller (e.g. enable the
controller when a set-value is applied and the field
current is C083 = 0A (motor not running))

l

Observe the signal flow at the monitor output term. 61
by means of an oscilloscope.

l

Reduce C084 so that the current can be controlled as
fast as possible without overshooting.

T

SR

< T

armature

Armature current controls too
slowly. Drive provides only little
dynamic response.

Increase of C084 under the same criteria as described
above.

7.1.3.2

n

max

setting

C011 maximum speed

The set-value setting range is determined through n

max

. Enter n

max

in rpm under

C011. n

max

can be between 250 rpm...5000 rpm. Default setting is 3000 rpm. n

max

is the reference value for the setting of the deceleration and acceleration times T

ir

and T

if

.

Stop!

If the additional set-value is added to the main set-value , the speed set-value C050
can reach up to 180% of n

max

.

Show/Hide Bookmarks