Configuration

7-88

48XX/49XXSHB0399

Code

Name

Possible settings

Code

Name

Lenze Selection

Info

C580*

Input 1,
Comparator 1

0 %

-100.0 %

{0.1 %}

+ 100.0 %

-200 %

{1 %}

+ 200 %

If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.

C581*

Input 2,
Limit value
for
comparator 1

0 %

-100.0 %

{0.1 %}

+ 100.0 %

-200 %

{1 %}

+ 200 %

If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.

C582*

Hysteresis for
lower
threshold
Comparator 1

0 %

0 %

{0.1 %}

+ 100 %

Lower threshold = C581 - C582,
reference: C581

C583*

¤ Memory

function
Comparator 1

-0-

Memory function not active
The output is reset when the value falls below
the lower threshold (C581 - C582)

-1-

Memory function active
The output remains set after initial switch on.

C584*

¤ Reset

function
Comparator 1

-0-

Reset function not active

-1-

Reset function active

The activation resets the output

C590*

Input 1,
Comparator 2

0 %

-100.0 %

{0.1 %}

+ 100.0 %

-200 %

{1 %}

+ 200 %

If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.

C591*

Input 2,
Limit value
for
comparator 2

0 %

-100.0 %

{0.1 %}

+ 100.0 %

-200 %

{1 %}

+ 200 %

If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.

C592*

Hysteresis for
lower
threshold
Comparator 2

0 %

0 %

{0.1 %}

+ 100 %

Lower threshold = C591 - C592,
reference: C591

C593*

¤ Memory

function
Comparator 2

-0-

Memory function not active
The output is reset when the value falls below
the lower threshold (C591 - C592)

-1-

Memory function active
The output remains set after initial switch on.

C594*

¤ Reset

function
Comparator 2

-0-

Reset function not active

-1-

Reset function active

The activation resets the output