Installation – Lenze EDS4900U-REG User Manual
Page 71
Advertising
![background image](/manuals/566281/71/background.png)
Installation
4-33
48XX/49XXSHB0399
4900Str021
L
P E
4
1 0
8
1
3
7
9
5
1 1
2
P E P E I K
A
B
6
FIG 4-23
Part of the CE-typical drive system with 4902 ... 4907 on a mounting plate
1
Connection mains fuse
2
RFI filter
3
Uncoated, bare metal contact surfaces
4
Commutating choke
5
Armature fuse
6
Metal plug-in casing connected to screen or Lenze system cable
7
Uncoated surface for screen connection
8
PE connection
9
Screened signal cables
10
Screened cables for act. value encoder or setpoint encoder
11
Motor connection
Show/Hide Bookmarks