5 checking the drive system, 1 checking the motor, Checking the drive system – Lenze EDS4900U-REG User Manual

Page 252: Checking the motor, Troubleshooting and fault elimination, 1 checking the motor warning

Advertising
background image

Troubleshooting and fault elimination

8-7

48XX/49XXSHB0399

8.5

Checking the drive system

Note!

The measurements should be made with a digital voltmeter. The stated measuring
values are rated values. In the event of deviations, a defect has occured.

8.5.1

Checking the motor

Warning!

( The measurements described must only be carried out by specialists.
( Disconnect the motor from the mains.
( Tests should only be carried out when no voltage is applied!

Measurement

Measuring point

Measured value

Armature resistance

A

“ B at the controller

R

A

< 10

W

Insulation resistance of the armature

A

“ earth potential

B

“ earth potential

R

“ Š

Field resistance

I

“ K

R

F

< 1k

W

Insulation resistance of the field

I

“ earth potential

K

“ earth potential

R

“ Š