Configuration – Lenze EDS4900U-REG User Manual

Page 225

Advertising
background image

Configuration

7-134

48XX/49XXSHB0399

Code

Possible settings

Name

Code

Info

Selection

Lenze

Name

[C146*] Function for

C145

-0-

No function

-1-

Main setpoint of C046

-2-

Input for torque selection

-3-

Additional setpoint of C049

-4-

V

pn

of the speed controller

-5-

Field current setpoint

-6-

Process controller: setpoint (C330)

-7-

Process controller: actual value

-8-

Process controller: evaluation (C331)

-9-

Process controller: ext. V

p

setting

-10-

C027 of X5

-11-

C027 of X9

-12-

Gearbox factor (C032)

-13-

Angle trimming of C256

-14-

Speed trimming of C257

-15-

Arithmetic block 2 - input 1 (C338)

-16-

Arithmetic block 2 - input 2 (C339)

-17-

Fixed setpoint block input

-18-

Analog / digital conversion 1 (C270)

-19-

Analog / digital conversion 2 (C271)

-20-

Dead band element input (C622)

-21-

DT1 element input (C652)

-22-

Absolute value generator input (C660)

-23-

Limiting element input (C632)

-24-

PT1 element input (C641)

-25-

Arithmetic block 3 - input 1 (C601)

-26-

Arithmetic block 3 - input 2 (C602)

-27-

Addition block 1 - input 1 (C610)

-28-

Addition block 1 - input 2 (C611)

-29-

Addition block 1 - input 3 (C612)

-30-

Addition block 2 - input 1 (C614)

-31-

Addition block 2 - input 2 (C615)

-32-

Addition block 2 - input 3 (C616)

-33-

Additional torque setpoint 1 (C148)

-34-

Additional torque setpoint 2 (C149)

-35-

FAI input of the S&H module

-36-

AIF process controller: act. value

-37-

Limiting element 2 input (C637)

-38-

Comparator 1 input 1 (C580)

-39-

Comparator 1 input 2 (C581)

-40-

Comparator 2 input 1 (C590)

-41-

Comparator 2 input 2 (C591)

-42-

Input for ext. excitation characteristic

-43-

n

act

of C051 (for tacho feedback)

-44-

n

act

of C051 (for resolver or incremental

encoder feedback)

-46-

Digital frequency setpoint

C146 = -4- V

pn

of the n-controller

corresponds to 0% at the input V

p2

under

C320 and

–100%at the input V

pn

under

C070.

C146 = -5- field current setpoint
correspond to

–100%at the input of the

rated current under C083. The minimum
adjustable value is determined under
C231.

C146 = -43-, -44-, -46- are for display
only (according to the configuration). They
cannot be assigned.

[C147*] Priority for C145

-0-

Terminal function not active, if terminal
control is switched-off under C001.

-1-

Terminal function remains active, if terminal
control is switched-off under C001.