Troubleshooting and fault elimination

8-1

48XX/49XXSHB0399

8

Troubleshooting and fault elimination

Warning!

During troubleshooting, the drive should always be disconnected from the mains
supply for safety reasons.

The controller is equipped with several functions to protect it from impermissible
operating conditions. If one of the protection functions is activated, the controller
sets Pulse Inhibit (IMP) or TRIP, warning or message and/or resets the signal
”Ready for operation (RDY) - depending on the monitoring selected.

( Faults during operation are immediately displayed or indicated through a

status information (chapter 8.1).

( The fault can be analysed with the history buffer (chapter 8.2) and the list in

chapter 8.3.

( The list in chapter 8.3 indicates how to eliminate the fault.

8.1

Troubleshooting

8.1.1

Display on the operating unit of the controller

The LEDs RDY and IMP show the controller status.

FAIL =

3

: TRIP or message or warning is active

FAIL

RDY

IMP

Check

P

3

P

Controller enabled; no fault

3

P

3

C065, C066, C067

P

P

3

C183, C067

P

3

3

C183

3

3

P

C065, C066

3

3

3

C065, C066, C067, C183

3 : on

P : off

Show/Hide Bookmarks