Configuration – Lenze EDS4900U-REG User Manual

Page 220

Advertising
background image

Configuration

7-129

48XX/49XXSHB0399

Code

Possible settings

Name

Code

Info

Selection

Lenze

Name

[C111*] Signal for C110

-0-

No signal

-1-

Main setpoint (C046), reference: n

max

-2-

Input ramp function generator, reference:
n

max

-3-

Output ramp function generator, reference:
n

max

-4-

Additional setpoint (C049), reference: n

max

-5-

n

set

at n-controller input (C050), reference:

n

max

Armature setting range: 100 % M

max

correspond to 100 % I

max

(C022, C023)

The actual armature current I

act

(C054) is

standardized, according to the controller:
I

act

X4/62,

X8

Type

X4/63

16A

4.4V

110kHz

4902

25A

4.7V

118kHz

4903

55A

4.8V

120kHz

4904

-6-

n

act

(C051), reference: n

max

(X4/63)

-8-

n

act

(C382), reference: n

max

(X8)

-20-

n-controller output, reference: M

max

-21-

M

set

(C047), reference: M

max

-22-

I

set

(C063), reference: I

max

(C022, C023),

(X4/62)

55A

4.8V

120kHz

4904

110A

4.9V

122kHz

4905

200A

6.4V

159kHz

4906

250A

4.4V

110kHz

4907

330A

5.2V

129kHz

4X08

500A

5.8V

144kHz

4X09

700A

5.8V

144kHz

4X11

-23-

I

act

(C054), reference: (see ’Info’)

-25-

M

set

(C056), reference: M

max

-28-

I

¼t load, reference: 100%

-29-

I

2

¼t load, reference: 100%

-30-

V

A

(C052), reference: 1000 V

700A

5.8V

144kHz

4X11

1000A 5.8V

146kHz

4X12

1200A 7.0V

175kHz

4X13

With C111 = -5- the selection depends on
the configuration set under C005.
If C005

6X

72 th

i

l C111

-35-

Mains frequency, reference: 30Hz = 0V,
70Hz = 10V

-40-

Fiel current setpoint, reference: max.
controller field current I

Fmax

-41-

Actual field current, reference: I

Fmax

-60-

Output motor potentiometer, reference:
100%

If C005 = -6X-, -72- the signal C111 =
-5- outputs the corresponding input pulse
current.

-61-

Output process controller, reference: 100%

-62-

Output arithmetic block 2, reference: 100%

-63-

Digital frequency input X5, reference: 100%

-64-

Digital frequency input X9, reference: 100%

-65-

Resolver, reference: 100%

-66-

Digital / analog conversion 1 (C272),
reference: 100%

-67-

Digital / analog conversion 2 (C273),
reference: 100%

-68-

Motor power, reference: 5 V = P

rated

-69-

Motor torque, reference: 5 V = M

rated

-70-

Output dead band element, reference: 100%

-71-

Output DT1 element, reference: 100%

-72-

Output absolute value generator, reference:
100%

-73-

Output limiting element 1, reference: 100%

-74-

Output PT1 element, reference: 100%

-75-

Output arith.-block 3, reference: 100%

-76-

Output add.-block 1, reference: 100%

-77-

Output add.-block 2, reference: 100%

-78-

Output limiting element 2, reference: 100%

Show/Hide Bookmarks

Advertising