Configuration

7-119

48XX/49XXSHB0399

7.9

Code table

How to read the code table:

Column

Abbreviation

Meaning

Code

C013

Code C013

l

The parameter value is accepted immediately (ONLINE).

C009*

l

Code of the extended code set

C001

¤

l

The parameter value of the code will be accepted after pressing SH+ PRG.

[C002]

l

The parameter value of the code will be accepted after pressing SH+ PRG,
but only if the controller is inhibited.

Name

Name of the code

Lenze

Factory setting of the code

Selection

1

{1 %}

99

Minimum value

{smallest step/unit}

maximum value

Info

-

Additional, important explanation of the code

Code

Name

Possible settings

Code

Name

Lenze

Selection

Info

C000

¤

Code set

1

-0-

(+ PW) Standard code set read only

Can only be changed via keypad!
If a password is defined under C094, a

-1-

(+ PW) Standard code set

If a password is defined under C094, a
change from -0- to -1- or -2- is only
possible after entering this password

-2-

(+ PW) Extendend code set

possible after entering this password
(+ PW):
1 Change C000 acknowledge with

SH

-9-

For service only

1. Change C000, acknowledge with

SH +

PRG

.

2 P

d

tti

ith ▲

-11-

Code set for automation module

2. Password setting with ▲ or ▼.
3. Accept with SH + PRG.

[C001]

Operating mode

0

Control

Parameter setting

-0-

Terminals

Keypad

-1-

Keypad

Keypad

-2-

Terminals

LECOM1

-3-

LECOM1

LECOM1

-4-

Terminals

LECOM2 (*)

-5-

LECOM2 (*) LECOM2 (*)

-6-

LECOM2 (*) Keypad

-7-

LECOM2 (*) LECOM1

(*) Fieldbus

With C001 =
-2-, -3-, -4-, -5-, -7-, TRIP must be reset
(C043) via the interface or the terminal.
With LECOM2, TRIP reset is also possible
via the control word of the process data
channel.

[C002]

Load parameter
set

0

-0-

Factory setting

-1-

Parameter set 1

-2-

Parameter set 2

-3-

Parameter set 3

-4-

Parameter set 4

Parameter set 1 is automatically loaded
after mains connection. If another
parameter set is selected via terminal, this
parameter set will also be loaded.

C003

¤ Save parameter

set

1

-1-

Parameter set 1

-2-

Parameter set 2

-3-

Parameter set 3

-4-

Parameter set 4

C004

¤ Switch-on

display

83

0

{1}

999

Code No. for switch-on display: Can only
be changed if C001= -0-, -1-, -6-