Technical Data
3-7
48XX/49XXSHB0399
( Controllers 4808 to 4813 (4Q controllers)
Type
4808
4809
4811
4812
4813
Order No.
EVD
4808-E-V014
EVD
4809-E-V014
EVD
4811-E-V014
EVD
4812-E-V014
EVD
4813-E-V014
Output power
1)
P
el
[kW]
189
287
402
575
690
Mains voltage
V
mains
3
ô 410...550 V~ á0%, 50...60Hz
Armature voltage
V
A
575 V if V
mains
= 500 V (1.15
¼ V
mains
)
Rated armature current
(continuous operation)
I
Arated
[A]
330
500
700
1000
1200
Maximum current (short-time
operation)
I
Amax
[A]
400
600
840
1200
1350
Field voltage
2)
V
F
V
Fmax
= 0.875
¼ V
L1-L3
Max. field current, controlled
I
F
[A]
15
30
Power loss
3)
P
loss
[W]
830
1220
2100
2850
3400
Ambient temperature in
operation
T
amb
[
C]
0...+ 35
4)
Weight approx.
[kg]
28
28
60
60
60
1)
referred to a mains voltage of 3
¼ 500V~
2)
The field is controlled as a current source, i.e. the field voltage depends on the field resistance.
3)
at rated armature current
4)
T
amb
$35°C: no power derating
,
35°C
T
amb
$45°C: power derating 1%/K