Configuration

7-21

48XX/49XXSHB0399

Code

Possible settings

Name

Code

Info

Selection

Lenze

Name

C029

¤ Automatic

adjustment
for C025

100%

This applies to all configurations:
If an automatic adjustment is not possible,
the previous value will be maintained.
--ok-- will not be displayed.

C007 = -5-, -6-, -9-, -20-:
Automatic adjustment for analog inputs
-100 %

{0.1 %}

100.0%

1.Inhibit controller.
2.Set setpoint at the terminal selected.
3.Enter the required values.
4.C027 displays the calculated gain

factor.

C025 = -2- and tacho at X1/3, X1/4 or
C025 = -5- and actual value from armature voltage

feedback:

n

act

adjustment

0 rpm

{1rpm}

5000rpm

Adjustment during operation:
1.Display of actual speed.
2.Measure real speed with hand tacho.
3.Enter real speed.
4.Drive accelerates to this speed.
5.C027 displays the calculated gain

factor.

C025 = -10-, -11-:
Adjustment of the digital frequency inputs X5, X9
-100.0 %

{0.1 %}

100.0%

Automatic adjustment only possible, if X5
or X9 are not selected as acutal speed
inputs:
1.Display of actual output value.
2.Enter required output value.
3.C027 displays the calculated gain

factor.

C025 = -12-:
Adjustment of the resolver
-100.0 %

{0.1 %}

100.0%

Automatic adjustment is only possible, if
the resolver is not used as speed
feedback system:
1.Display of actual output value.
2.Enter required output value.
3.C027 displays the calculated gain

factor.