Configuration

7-26

48XX/49XXSHB0399

Code

Name

Possible settings

Lenze

Selection

Info

C116*

¤ Input

selection:
Freely
assignable
digital
output

1

-1-

FDO 1

-2-

FDO 2

...
-12-

FDO 12

-13-

Relay output X3/K11, X3/K14

The digital outputs FDO1..FDO12 and the
relay output X3/K11, X3/K14 are freelay
assignable with the functions under C117.
Multiple assignment is possible.
The outputs FDO1...FDO5 are assigned to
the terminals X3/A1...X3/A5.
FDO6...FDO12 can only be accessed via
LECOM.
Assignment of functions:
1.Select output under C116.
2.Assign function under C117.
Only for FDO1...FDO5, relay output:
3.Determine polarity under C118.
4.Determine signal delay under C128.

[C117*] Function

for C116

-0-

No function

-1-

n

act

ˆ n

x

C017 (FDO1)

-2-

Controller enabled (FDO10)

-3-

n-controller output = M

max

(FDO2)

-4-

Ready for operation (RDY) (FDO11)

-5-

Pulse inhibit (IMP) (FDO12)

-6-

TRIP (relay)

-7-

Warning (FDO6)

-8-

Message (FDO7)

-9-

Ramp function generator Input = Output
(FDO3)

-10-

n

act

= n

set

(FDO5)

-11-

n

act

= 0 (FDO4)

-12-

I

A

= 0 (FDO8)

-13-

I

A

& n

act

= 0 (FDO9)

-14-

C046 or C049 > n

x

(Threshold C243)

-15-

|I

A

| > I

x

(Threshold C244)

-16-

I

F

> I

x

(Threshold C245)

-17-

|n

act

| > n

x

(Threshold C242)

-18-

Brake control

-19-

Comparator 1

-20-

Comparator 2

[C118]

Polarity for
C116

-0-

Output is HIGH active (FDO2, 3, 5)

-1-

Output is LOW active (FDO1, 4, relay)

C128*

Delay for
C116

0.000 s 0.000 s

{0.001 s}

240.000 s

Signal delay times for FDO 1...5 and relay