2 mains voltage 500v (variant v014), Mains voltage 500v (variant v014), Technical data – Lenze EDS4900U-REG User Manual

Page 34

Advertising
background image

Technical Data

3-6

48XX/49XXSHB0399

3.3.2

Mains voltage 500V (Variant V014)

( Controllers 4903 to 4907 (4Q controllers)

Type

4903

4904

4905

4906

4907

Order No.

EVD

4903-E-V014

EVD

4904-E-V014

EVD

4905-E-V014

EVD

4906-E-V014

EVD

4907-E-V014

Output power

1)

P

el

[kW]

13.1

28.8

57.7

105

131

Mains voltage

V

mains

3

ô410...550 V~ –0%, 50...60 Hz

Armature voltage

V

A

525 V if V

mains

= 500V (1.05

¼ V

mains

)

Rated armature current
(continuous operation)

I

Arated

[A]

25

55

110

200

250

Maximum current (short-time
operation)

I

Amax

[A]

45

90

150

240

300

Field voltage

2)

V

F

V

Fmax

= 0.875

¼ V

L1-L3

Max. field current, controlled

I

F

[A]

3.5

10

Power loss

3)

P

loss

108

185

288

577

650

Ambient temperature in
operation

T

amb

[

•C]

0...+ 45

0...+ 35

4)

Weight approx.

[kg]

13.1

13,8

18

22

23

( Controllers 4908 to 4913 (4Q controllers)

Type

4908

4909

4911

4912

4913

Order No.

EVD

4908-E-V014

EVD

4909-E-V014

EVD

4911-E-V014

EVD

4912-E-V014

EVD

4913-E-V014

Output power

1)

P

el

[kW]

173

262

367

525

630

Mains voltage

V

mains

3

ô 410...550 V~ á0%, 50...60Hz

Armature voltage

V

A

525 V if V

mains

= 500 V (1.05

¼ V

mains

)

Rated armature current
(continuous operation)

I

Arated

[A]

330

500

700

1000

1200

Maximum current (short-time
operation)

I

Amax

[A]

400

600

840

1200

1350

Field voltage

2)

V

F

V

Fmax

= 0.875

¼ V

L1-L3

Max. field current, controlled

I

F

[A]

15

30

Power loss

3)

P

loss

[W]

840

1220

2100

2850

3400

Ambient temperature in
operation

T

amb

[

•C]

0...+ 35

4)

Weight approx.

[kg]

28

28

60

60

60

Show/Hide Bookmarks

Advertising