Selection aid

15-14

48XX/49XXSHB0399

Parameter setting

Code

Input

Description

Input according to motor nameplate

C083

xxx A

Rated field current

C084

xxx ms

Armature-time constant

C088

xxx A

Rated motor current

C090

xxx V

Rated motor voltage

Input of current limits

C022, C023

xxx A

Maximum motor current

Enter controller configuration

C000

-2-

Extended code set

C005

-52-

Speed control with phase controller

Adjustment of speed controller

C070

V

pn

At high inertias, adapt n - controller gain

Adjustment of the phase controller

C254

V

pw

Adapt V

pw

to the system, if V

pw

= 0, the phase controller is not

activated.

Application parameters

C011

xxx rpm

Enter max. speed (this speed corresponds to v

max

)

C019

xxx rpm

Set threshold n

act

= 0

C240

xxx % n

max

Setting of the permissible speed deviation

C116

-5-

Input selection of the digital output A5

C128

xxx s

Time, during which the drive can leave the selected range, without a
message being sent

C255

xxxx incr

Following error limit

C105

xxx s

Deceleration time t

f

= 2

: s / v

pos

C116

-1-

Input selection of the digital output A1

C117

-15-

I

act

> I

x

C244

xxx %

I

max

(limit value for the starting torque against the brake)

C038

-1-

Input selection JOG 1

C039

xxx %

C011 (save speed for v

pos

in JOG 1)

C038

-x-

Input selection JOG x

C039

xxx %

C011 (other speeds)

Save parameter

C003

Save parameter set

Show/Hide Bookmarks