Configuration

7-104

48XX/49XXSHB0399

Code

Name

Possible settings

Code

Name

Lenze Selection

Info

C119*

¤ Selection of

monitoring
function

-15-

OC5

-16-

OC6

-22-

OUE

-31-

LU1

-32-

LU

-41-

LF

-42-

OF

-50-

OH

-61-

CE0

-70-

U15

-80-

SP

-81-

Sd1

-82-

Sd2

-83-

Sd3

-84-

Sd4

-85-

Sd5

-91-

EEr

-93-

dEr

-94-

ACI

-96-

FCI

-153-

P03

-163-

P13

-69-

CE9

I

¼t overload (controller protection)

I

2

¼t overload (motor protection)

Mains overvoltage
Phase fault
Mains undervoltage
Mains underfrequency f

Mains

< 47Hz

Mains overfrequency f

Mains

> 63Hz

Overtemperature heat sink
Communication error (automation
interface)
– 15V failure
Wrong signal source polarity
Tacho short circuit/interruption
Open circuit of resolver
Encoder fault at X5
Encoder fault at X9
Defective setpoint encoder
Ext. TRIP terminal
Motor blocked
Interruption of armature circuit
Interruption of field circuit
Following error
Angle overflow
Communication error (serial interface)

[C120*] Change of

monitoring
function

-0-

TRIP

-1-

Warning

-2-

Message with pulse inhibit

-3-

Message without pulse inhibit

-4-

Switched-off

The important monitoring functions are set
according to the change of configuration
under C005.

C123

Current
threshold
for blocking
protection
for C124

0.95
I

rated

0 A

{0.1A}

100 A

100 A

{1 A}

3600 A

Rated current depends on the controller:
0 ... 87A

(4902)

0 ... 135A

(4903)

0 ... 270A

(4904)

0 ... 450A

(4905)

0 ... 720A

(4906)

0 ... 900A

(4907)

0 ... 1200A

(4X08)

0 ... 1800A

(4X09)

0 ... 2520A

(4X11)

0 ... 3600A

(4X12)

0 ... 4050A

(4X13)

See motor nameplate

C124*

Blocking
time

60 s

1 s

{1 s}

100 s

Motor standstill time until fault message is
activated