3 connection, Installation – Lenze EDS4900U-REG User Manual

Page 43

Advertising
background image

Installation

4-5

48XX/49XXSHB0399

4.3

Connection

Connection between controller and motor

Lenze controller

Motor (to DIN 42017/VDE 0530 part 8)

Function

Terminal

Terminal

Others

Motor type

Armature voltage

Excitation voltage

+
-
+
-

A
B
I
K

1B1
2B2
F1
F2

A1
B2, A2
F5, (for higher connection voltages)
F2

DC motor
uncompensated with
commutating winding

Armature voltage

Excitation voltage

+
-
+
-

A
B
I
K

1C1
2C2
F1
F2

A1
C2
F5, (for higher connection voltages)
F2

DC motor
compensated with
commutating winding

Armature voltage

+
-

A
B

A1
A2

Permanent-magnet
motor

DC tacho

+
-

3
4

2A1
2A2

Temp. switch

S1, S2

Thermal contact

T1, T2

Screw-tightening torques

Type

4902

4903 - 4904

4905 - 4907

4X08 - 4X09

4X11 - 4X13

L1, L2, L3, A, B

0.5 ... 0.6 Nm

2.0 ... 2.4 Nm

37 Nm

1)

64 Nm

1)

A, B

0.5 ... 0.6 Nm

2.0 ... 2.4 Nm

37 Nm

1)

15 ... 20 Nm

64 Nm

L1.1, L3.1, I, K

0.5 ... 0.6 Nm

1.2 ... 1.5 Nm

L1.2, L2.2, L3.2

0.5 ... 0.6 Nm

L1.3, L2.3, L3.3, 86 - 89

-

0.5 ... 0.6 Nm

Terminal strip X1 - X4

0.5 ... 0.6 Nm

1)

Rated tightening torque for the connection of terminal ends to busbars

(VDE 0220 part 1/11.71)

When continued with busbar see DIN 43673 part 1/02.82

The following circuit diagrams show the electrical wiring of the power connections.

Show/Hide Bookmarks

Advertising