Configuration – Lenze EDS4900U-REG User Manual

Page 94

Advertising
background image

Configuration

7-3

48XX/49XXSHB0399

Code

Name

Possible settings

Code

Name

Lenze Selection

Info

C038

¤ Input

preselection:
JOG
set-value

1

-1-

Selection JOG1

-2-

Selection JOG2

...
-15-

Selection JOG15

Select JOG setpoint to be set under C039.

C039

JOG speed
for C038

-100 % n

max

{0.1 %}

+ 100.0 % n

max

100.0%

JOG1

75.0%

JOG2

50.0%

JOG3

25.0%

JOG4

0.0 %

JOG5

..

...

0.0 %

JOG15

Enable JOG set-values via the digital
inputs or via C045.

Assignment of the digital inputs

The number of inputs to be assigned with the function ”enable JOG set-value”,
depends on the number of JOG set-values required.

Number of JOG set-values required

Number of inputs required

1

at least 1

2...3

at least 2

4...7

at least 3

8...15

4

This function can be assigned to up to four inputs.
For input assignment, observe the notes in chapter 5.6.

JOG set-value enabling with terminal control

The assigned digital inputs must be controlled according to the table below to
enable JOG set-values.

2. input

3. input

4. input

JOG 1

1

0

0

0

JOG 2

0

1

0

0

JOG 3

1

1

0

0

JOG 4

0

0

1

0

JOG 5

1

0

1

0

JOG 6

0

1

1

0

JOG 7

1

1

1

0

JOG 8

0

0

0

1

JOG 9

1

0

0

1

JOG 10

0

1

0

1

JOG 11

1

1

0

1

JOG 12

0

0

1

1

JOG 13

1

0

1

1

JOG 14

0

1

1

1

JOG 15

1

1

1

1

The input with the lowest figure is the first input, the input with the next higher figure
is the second input, and so on (e. g. E4 = 1. input, E5 = 2. input).

C045 indicates the active set-value.

Show/Hide Bookmarks

Advertising