Configuration

7-90

48XX/49XXSHB0399

If the inputs are not assigned, constant values can be assigned via the input
codes. These values can also be stored in EEPROM via C003.

2. Function

The additional torque set-values have a summing influence on the n controller
output. The sum of these signals is limited to

–100%.

Code

Name

Possible settings

Code

Name

Lenze Selection

Info

C148

Additional
torque
value 1

0

-100.0 % M

max

{0.1 %}

+ 100.0 % M

max

-200 % M

max

{1%}

+ 200 % M

max

Display only with terminal control. If the
terminal control is deactivated, the actual
terminal value will be accepted for
operation. In the armature setting range:
100 % M

max

correspond to 100 % I

max

(C022, C023)

C149

Additional
torque
value 2

0

-100.0 % M

max

{0.1 %}

+ 100.0 % M

max

-200 % M

max

{1%}

+ 200 % M

max

Display only with terminal control. If the
terminal control is deactivated, the actual
terminal value will be accepted for
operation. In the armature setting range:
100 % M

max

correspond to 100 % I

max

(C022/C023)

7.6.2

Speed dependent armature current limitation

4900Str078

-

+

2

1

C 0 4 7

C 0 5 0

+

C 0 5 1

4 0

4 2

4 3

4 1

+

C 1 4 5 / C 1 4 6

C 0 2 5 / C 0 2 7

3

4

± 1 8 0 V

C 2 7

C 2 8

C 2 5 / C 2 6

C 0 2 5 / C 0 2 7

-

A B

Q S P

C 0 7 0 V

C 0 7 1 T

C 0 7 2 K

p n

n n

d n

C 0 5 6

C 0 6 3

C 0 2 2 , C 0 2 3

C 3 1 0

C 3 1 1

C 3 1 2

C 3 1 3

C 3 1 4

C 0 2 5 / C 0 2 6

C 0 2 5 / C 0 2 6

C 0 2 5 / C 0 2 7

C 1 4 5 / C 1 4 6

+

+

C 1 4 8

C 1 4 9

C 1 4 6 / C 1 4 7

C 1 4 6 / C 1 4 7

+

-

1 0 0 %

C 2 8 2

C 1 9 8

n

s e t

a t n - c o n t r o l l e r

i n % o f n

m a x

n a c t

n

o f f s e t

T a c h o

I n c r e m e n t a l

e n c o d e r

R e s o l v e r

I

a c t

V

a r m a t u r e v o l t a g e

C 2 3 2

I · R - c o m p e n s a t i o n

0 V = n o t o r q u e

1 0 V = m a x . t o r q u e

E x t e r n a l t o r q u e l i m i t

C 0 0 5 C o n f i g u r a t i o n

n - c o n t r o l l e r

M

s e t

i n %

o f M

m a x

I

s e t

I

m a x

I

F a c t

A d d i t i o n a l t o r q u e s e t p o i n t 1

A d d i t i o n a l t o r q u e s e t p o i n t 2

s p e e d - d e p e n d e n t

c u r r e n t l i m i t a t i o n

E n c .

c o n s t .

FIG 7-51

Signal-flow chart (section) for speed-dependent armature current limitation

Purpose

If DC machines are drive with rated armature current in field weakening operation,
the segment voltage (at the armature) can reach impermissibly high values.