Acceleration and deceleration times T

ir

,T

if

Each acceleration or deceleration time refers to a speed change from 0 to n

max

(C011). The times T

ir

and T

if

to be set can be calculated as follows:

m a x

0

t i r

t i f

T i r

T i f

t

n

[ r p m ]

n

n

n 2

1

T = t

i r i r

n

n - n

2 1

m a x

T = t

i f i f

n

n - n

2 1

m a x

a c t

4900Str030

FIG 7-3

Calculation of acceleration and deceleration time

Here t

ir

and t

if

correspond to the times desired for the change from n

1

to n

2

and

vice versa.
The times T

ir

and T

if

calculated are setting values for the controller.

( Acceleration and deceleration time C012 and C013
The ramp function generator of the main set-value (n

set

or JOG set-value)is set via

the times T

ir

and T

if

under C012 and C013.

( Additonal acceleration and deceleration times
Alternaltively to the acceleration and deceleration times under C012 and C013,
additional T

ir

and T

if

times can be retrieved from the memory, for instance, to

change the drive acceleration from a certain speed on.

Programming of additional acceleration and deceleration times

Set the additional T

i

times in two steps. The selection under C100 is valid for a pair

of acceleration and deceleration times:

( Select additional acceleration/deceleration times under C100.
( Enter the required acceleration time under C101, and the deceleration time

under C103.

For several additional T

i

times repeat these two steps as often as required.

A maximum of 15 additional acceleration and deceleration times can be
programmed.