Selection aid
15-7
48XX/49XXSHB0399
Parameter setting
Code
Input
Description
Input according to motor nameplate
C083
xxx A
Rated field current
C084
xxx ms
Armature-time constant
C088
xxx A
Rated motor current
C090
xxx V
Rated motor voltage
Input of current limits
C022, C023
xxx A
Maximum motor current
Enter controller configuration
C000
-2-
Extended code set
C005
-42-
Torque control with speed limitation
Adjustment of speed controller
C011
xxxx rpm
Max. max. speed
Application parameters
C019
xxxx rpm
Set threshold n
act
= 0
C016
xxxx rpm
Reference speed n
act
n
x
C070
V
pn
At high inertias, adapt n - controller gain