Configuration

7-141

48XX/49XXSHB0399

Code

Possible settings

Name

Code

Info

Selection

Lenze

Name

C336*

Actual V

p

of the

process
controller

0.1

{0.1}

500.0

Display: Actual gain factor of the process
controller (important for process controller
adaption)

C338*

Input 1,
arithmetic
block 2

0%

-100.0 %

{0.1 %}

100.0 %

-200 %{1 %}

+ 200 %

If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.

C339*

Input 2,
arithmetic
block 2

0%

-100.0 %

{0.1 %}

100.0 %

-200 %

{1 %}

+ 200 %

If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.

C370*

¤ Enable

automation
interface

-0-

No communication via automation interface

-1-

Communication via automation interface
enabled

C380*

n

set

speed

-16384

{1}

16384

High precision main setpoint selection:
16384

Ÿ 100%under C046

Input only via interface.

C381*

n

set

at

n-controller

-32767

{1}

32767

High precision setpoint display:
Input of the speed controller,
16384

Ÿ 100%under C050.

Input only via interface.

C382*

Actual speed

-32767

{1}

32767

High precision display: Act. speed value
16384

Ÿ n

max

under C011.

Input only via interface.

C387*

Torque limit

-16384

{1}

16384

High precision torque setpoint selection:
16384

Ÿ 100%under C047.

Input only via interface.

C388*

Torque setpoint

-16384

{1}

16384

High precision torque setpoint display:
16384

Ÿ 100%under C056.

Input only via interface.

C391*

Actual angle

0

{1}

65535

High precision display of the actual angle
if resolver or incremental encoder operate
as feedback system:
16384

Ÿ 360• Ÿ1 revolution.

Input only via interface.

C392*

Field current
setpoint

0

{1}

16384

High precision display of the field current
setpoint:
16384

Ÿ I

FN

under C083.

Input only via interface.

C393*

Additional
setpoint

-16384

{1}

16384

High precision additional setpoint display:
16384

Ÿ 100%under C049.

Input only via interface.

C580*

Input 1,
comparator 1

0 %

-100.0 %

{0.1 %}

+ 100.0 %

-200 %

{1 %}

+ 200 %

If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.

C581*

Input 2,
limit value for
comparator 1

0 %

-100.0 %

{0.1 %}

+ 100.0 %

-200 %

{1 %}

+ 200 %

If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.

C582*

Hysteresis for
lower threshold
comparator 1

0 %

0.0 %

{0.1 %}

+ 100.0 %

Lower threshold = C581 - C582,
reference: C581

C583*

Memory
function
comparator 1

-0-

Memory function not active
when resetting the output, the value falls below
the lower threshold (C581 - C582)

-1-

Memory function active
The output remains set after inital switching
on.

C584*

¤ Reset function

comparator 1

-0-

Reset function not active

-1-

Reset function active

The activation resets the output.