Configuration – Lenze EDS4900U-REG User Manual
Page 232
![background image](/manuals/566281/232/background.png)
Configuration
7-141
48XX/49XXSHB0399
Code
Possible settings
Name
Code
Info
Selection
Lenze
Name
C336*
Actual V
p
of the
process
controller
0.1
{0.1}
500.0
Display: Actual gain factor of the process
controller (important for process controller
adaption)
C338*
Input 1,
arithmetic
block 2
0%
-100.0 %
{0.1 %}
100.0 %
-200 %{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
C339*
Input 2,
arithmetic
block 2
0%
-100.0 %
{0.1 %}
100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
C370*
¤ Enable
automation
interface
-0-
No communication via automation interface
-1-
Communication via automation interface
enabled
C380*
n
set
speed
-16384
{1}
16384
High precision main setpoint selection:
16384
100%under C046
Input only via interface.
C381*
n
set
at
n-controller
-32767
{1}
32767
High precision setpoint display:
Input of the speed controller,
16384
100%under C050.
Input only via interface.
C382*
Actual speed
-32767
{1}
32767
High precision display: Act. speed value
16384
n
max
under C011.
Input only via interface.
C387*
Torque limit
-16384
{1}
16384
High precision torque setpoint selection:
16384
100%under C047.
Input only via interface.
C388*
Torque setpoint
-16384
{1}
16384
High precision torque setpoint display:
16384
100%under C056.
Input only via interface.
C391*
Actual angle
0
{1}
65535
High precision display of the actual angle
if resolver or incremental encoder operate
as feedback system:
16384
360 1 revolution.
Input only via interface.
C392*
Field current
setpoint
0
{1}
16384
High precision display of the field current
setpoint:
16384
I
FN
under C083.
Input only via interface.
C393*
Additional
setpoint
-16384
{1}
16384
High precision additional setpoint display:
16384
100%under C049.
Input only via interface.
C580*
Input 1,
comparator 1
0 %
-100.0 %
{0.1 %}
+ 100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
C581*
Input 2,
limit value for
comparator 1
0 %
-100.0 %
{0.1 %}
+ 100.0 %
-200 %
{1 %}
+ 200 %
If an analog signal source (C145/C146) is
assigned, the parameter will be displayed
only.
C582*
Hysteresis for
lower threshold
comparator 1
0 %
0.0 %
{0.1 %}
+ 100.0 %
Lower threshold = C581 - C582,
reference: C581
C583*
Memory
function
comparator 1
-0-
Memory function not active
when resetting the output, the value falls below
the lower threshold (C581 - C582)
-1-
Memory function active
The output remains set after inital switching
on.
C584*
¤ Reset function
comparator 1
-0-
Reset function not active
-1-
Reset function active
The activation resets the output.