Installation

4-22

48XX/49XXSHB0399

The resolver signal or encoder signal can be output for following drives at the digital
frequency output X8.

( Connection as shown in the connection diagrams:

- Use cables twisted and screened in pairs.

- Connect both screen ends.

- Use cable cross-sections indicated.

( The feedback system can be activated under C005.
( If resolvers are used which are not specified by Lenze are used, contact

your Lenze representative.

Incremental encoder feedback

( Incremental encoders with two 5 V complementary signals electrically

shifted by 90

•(TTL encoders) or HTL encoders can be connected.

( Connection to a 9-pole Sub D socket X5 or X9, depending on the

configuration of C005

- Maximum input frequency:

420 kHz with TTL encoder
100 kHz with HTL encoder

- Current consumption per channel: 6 mA

( With HTL signal:

- If there is no inverse track available, the

inputs A and B (with zero track also Z ) must be connected to the
encoder supply potential.

B

A

VE9

GND

Z

Z

1

2

3

4

5

6

7

8

9

A

B

A

B

A

B

Z

Z

l

max

= 50 m



4900Sttr016

FIG 4-16

Incremental encoder connection (9-pole Sub D socket)

Show/Hide Bookmarks