Configuration – Lenze EDS4900U-REG User Manual

Page 211

Advertising
background image

Configuration

7-120

48XX/49XXSHB0399

Code

Possible settings

Name

Code

Info

Selection

Lenze

Name

[C005*] Configuration

11

Speed control with additional setpoint

-10-

Armature voltage control
n

set

: analog at X1/8

n

add

: analog at X1/6

M

limit

: analog at X1/1, 1/2.

-11-

Act. value encoder: tacho at X1/3,X1/4
n

set

: analog at X1/8

n

add

: analog at X1/6

M

limit

: analog at X1/1, X1/2

-12-

Act. value encoder: resolver at X7
n

set

: analog at X1/8

n

add

: analog at X1/6

M

limit

: analog at X1/1, X1/2

-13-

Act. value encoder: increment. encoder at X9
n

set

: analog at X1/8

n

add

: analog at X1/6

M

limit

: analog at X1/1, X1/2

If C005 = -10- or -40-, field control
override is not possible.
A change of the configuration changes the
control structure and the terminal
assignment and activates important
monitoring functions.
Change monitoring functions:
C119 / C120
Change terminal signals: C145 / C146.

Torque control with speed limitation and addi-
tional setpoint

-40-

Armature voltage control
n

set

: analog at X1/8

n

add

: analog at X1/6

M

set

: analog at X1/1, 1/2.

-41-

Act. value encoder: tacho at X1/3, X1/4
n

set

: analog at X1/8

n

add

: analog at X1/6

M

set

: analog at X1/1, 1/2.

-42-

Act. value encoder: resolver at X7
n

set

: analog at X1/8

n

add

: analog at X1/6

M

set

: analog at X1/1, X1/2

-43-

Act. value encoder: increment. encoder at X9
n

set

: analog at X1/8

n

add

: analog at X1/6

M

set

: analog at X1/1, X1/2

Dig. freq. of master with additional setpoint

-52-

Act. value encoder: resolver at X7
n

set

: analog at X1/8

n

add

: analog at X1/6

M

limit

: analog at X1/1, X1/2

-53-

Act. value encoder: increment. encoder at X5
n

set

: analog at X1/8

n

add

: analog at X1/6

M

limit

: analog at X1/1, X1/2

Digital frequency bus

-62-

Act. value encoder: resolver at X7
n

set

: digital at X9

M

limit

: analog at X1/1, X1/2

-63-

Act. value encoder: increment. encoder at X5
n

set

: digital at X9

M

limit

: analog at X1/1, X1/2

Digital frequency cascade

-72-

Acutal value encoder: resolver at X7
n

set

: digital, X5

M

limit

: analog at X1/1, X1/2

C009*

¤ Controller

address

1

1

{1}

99

Bus participant number for operation via
interface: Parameter 10 reserved for
broadcasting to groups of participants.
Can only be changed with C001 = -0-
and -1-.

Show/Hide Bookmarks