7-34

48XX/49XXSHB0399

Code

Possible settings

Name

Code

Info

Selection

Lenze

Name

[C111*] Signal for

C110

-0-

No signal

-1-

Main set-value (C046), reference: n

max

-2-

Input ramp function generator, reference: n

max

-3-

Outut ramp function generator, reference: n

max

-4-

Additional set-value (C049), reference: n

max

-5-

n

set

at the n controller input (C050), reference:

n

max

In the armature setting range: 100 %
M

max

correspond to 100 % I

max

(C022,

C023)
The actual armature current value I

act

(C054) is normalised according to the
controller:
I

act

X4/62, X4/63

X8

Type

16A

4 4V

110kHz

4902

-6-

n

act

(C051), reference: n

max

(X4/63)

-8-

n

act

(C382), reference: n

max

(X8)

-20-

n controller output, reference: M

max

-21-

M

set

(C047), reference: M

max

-22-

I

set

(C063), reference: I

max

(C022, C023),

(X4/62)

16A

4.4V

110kHz

4902

25A

4.7V

118kHz

4903

55A

4.8V

120kHz

4904

110A

4.9V

122kHz

4905

200A

6.4V

159kHz

4906

250A

4.4V

110kHz

4907

330A

5 2V

129kHz

4X08

-23-

I

act

(C054), reference: (see ’Info’)

-25-

M

set

(C056), reference: M

max

-28-

I

¼t load, reference: 100%

-29-

I

2

¼t load, reference: 100%

-30-

V

A

(C052), reference: 1000 V

330A

5.2V

129kHz

4X08

500A

5.8V

144kHz

4X09

700A

5.8V

144kHz

4X11

1000A

5.8V

146kHz

4X12

1200A

7.0V

175kHz

4X13

-35-

Mains frequency, reference: 30Hz = 0V, 70Hz
= 10V

-40-

Field current set-value, reference: max. rated
field current I

Fmax

-41-

Actual field current, reference: I

Fmax

-60-

Output motor potentiometer, reference: 100%

-61-

Output process controller, reference: 100%

-62-

Output arithmetic block 2, reference: 100%

-63-

Digital frequency input X5, reference: 100%

-64-

Digital frequency input X9, reference: 100%

-65-

Resolver, reference: 100%

-66-

Digital / analog conversion 1 (C272), reference:
100%

-67-

Digital / analog conversion 2 (C273), reference:
100%

-68-

Motor power, reference: 5 V = P

rated

-69-

Motor torque, reference: 5 V = M

rated

-70-

Output dead band element, reference: 100%

-71-

Output DT1 element, reference: 100%

-72-

Output absolute value generator, reference:
100%

-73-

Output limitation element 1, reference: 100%

-74-

Output PT1 element, reference: 100%

-75-

Output arithmetic block 3, reference: 100%

-76-

Output addition block 1, reference: 100%

-77-

Output addition block 2, reference: 100%

Show/Hide Bookmarks

Advertising