2 general data / application conditions, General data / application conditions, Technical data – Lenze EDS4900U-REG User Manual

Page 31

Advertising
background image

Technical Data

3-3

48XX/49XXSHB0399

3.2

General data / application conditions

Field

Values

Type of protection

IP20 to DIN 40050, steel sheet housing

Permissible humidity

Relative humidity 90%, no condensation

Temperature ranges

Storage

-25

•C...+ 55 •C

Transport

-25

•C...+ 70 •C

Influence of the installation height

h

$ 1000m : 100%rated armature current

h

$ 2000m : 95%rated armature current

h

$ 3000m : 90%rated armature current

h

$ 4000m : 85%rated armature current

Degree of pollution

VDE 0110, part 2, degree of pollution 2
Controllers must not be exposed to a corrosive or explosive
atmo-sphere.

Noise emission

Requirements to EN 50081-2, IEC 22G
Limit-value class A (EN 55011; industrial premises) with RFI filter

Noise immunity

Limit values maintained with RFI filter.
Requirements to EN 50082-2, IEC 22G
Requirements

Standard

Severity

ESD

EN 61000-4-2

3, i.e. 8kV air discharge
6 kV contact discharge

RF interference

IEC 1000-4-3

3, i.e. 10 V/m

(enclosure)
Burst

EN 61000-4-4

3/4, i.e. 2kV / 5kHz

Surge

EN 61000-4-5

3, i.e. 1.2 / 50

ms

1kV phase - phase
2kV phase - PE

Show/Hide Bookmarks