Code
Name
Possible settings
Lenze Selection
Info
C310* Speed-dependent
current limitation
Limit value 1
100% 0.0 %
{0.1 %}
+ 100.0 %
Valid for speed under C313
C310
must be higher than C311!
C311* Speed-dependent
current limitation
Limit value 2
100% 0.0 %
{0.1 %}
+ 100.0 %
Valid for speed under C314
C311
must be smaller than C310!
C312* n0
Speed-dependent
current limitation
3000
rpm
0 rpm
{1 rpm}
5000 rpm
Actual speed threshold (activation of
current limitation), condition: n
1
> n
0
C313* n1
Speed-dependent
current limitation
4000
rpm
0 rpm
{1 rpm}
5000 rpm
Actual speed threshold for limit value 1,
condition: n
2
> n
1
> n
0
C314* n2
Speed-dependent
current limitation
5000
rpm
0 rpm
{1 rpm}
5000 rpm
Actual speed threshold for limit value 2,
condition: n
2
> n
1
> n
0
For more detailed information see the motor catalogue or contact the
manufacturer.