Configuration

7-92

48XX/49XXSHB0399

Code

Name

Possible settings

Lenze Selection

Info

C310* Speed-dependent

current limitation
Limit value 1

100% 0.0 %

{0.1 %}

+ 100.0 %

Valid for speed under C313

C310

must be higher than C311!

C311* Speed-dependent

current limitation
Limit value 2

100% 0.0 %

{0.1 %}

+ 100.0 %

Valid for speed under C314

C311

must be smaller than C310!

C312* n0

Speed-dependent
current limitation

3000

rpm

0 rpm

{1 rpm}

5000 rpm

Actual speed threshold (activation of
current limitation), condition: n

1

> n

0

C313* n1

Speed-dependent
current limitation

4000

rpm

0 rpm

{1 rpm}

5000 rpm

Actual speed threshold for limit value 1,
condition: n

2

> n

1

> n

0

C314* n2

Speed-dependent
current limitation

5000

rpm

0 rpm

{1 rpm}

5000 rpm

Actual speed threshold for limit value 2,
condition: n

2

> n

1

> n

0