12 freely assignable comparator, N controller adaptation, Configuration – Lenze EDS4900U-REG User Manual
Page 177
![background image](/manuals/566281/177/background.png)
Configuration
7-86
48XX/49XXSHB0399
7.5.12
Freely assignable comparator
The freely assignable comparators generate a digital output signal which depends
on the analog input signals.
4900Str074
C 1 4 6 / C 1 4 7
C 1 4 5 / C 1 4 6
C 5 8 0
S
R
C 5 8 1
C 5 8 4
C 5 8 2
0
1
C 5 8 3
R e s e t
I n p u t 2
I n p u t 1
a n a l o g o u t p u t
d i g i t a l o u t p u t
FIG 7-47
Comparator 1
4900Str075
C 1 4 6 / C 1 4 7
C 1 4 5 / C 1 4 6
C 5 9 0
S
R
C 5 9 1
C 5 9 4
C 5 9 2
0
1
C 5 9 3
R e s e t
I n p u t 2
I n p u t 1
a n a l o g o u t p u t
d i g i t a l o u t p u t
FIG 7-48
Comparator 2
Inputs:
With the function ”freely assignable inputs” each analog input of the comparator
can be assigned to a ”terminal signal” from the table according to C145. The input
values are compared in the range of
200 %.
With the function ”freely programmable digital inputs”, the reset input can be
connected with a signal source according to the table under code C112.
”Analog” output:
With the function ”freely assignable inputs” the inputs C580 for comparator 1 and
C590 for comparator 2 can be used for further processing tasks. It is possible, for
example, to compare the signal at the analog input terminal 8 with a limit value and
provide the main set-value.
”Digital” output:
With the function ”freely assignable digital outputs”, the result of the comparator
can be assigned to an output according to the table under C116.
Show/Hide Bookmarks