2 torque control with speed limitation, Configuration, Stop – Lenze EDS4900U-REG User Manual

Page 128

Advertising
background image

Configuration

7-37

48XX/49XXSHB0399

7.2

Torque control with speed limitation

Purpose

The drive is changed to torque control by the setting the configuration to C005 =
-4X- ”torque control with speed limitation”. The torque can be entered in both
directions.

In different operating modes, the speed is monitored with a speed limitation by
means of the n-controller.

Parameter setting

Stop!

With a negative torque set-value , the speed limitation is not effective. The drive can
reach impermissibly an impermissibly high speed, which can damage motor or
machine. These applications can only be monitored with the digital ouput

act

$ n

x

.

For standard applications, the drive can be immediately commissioned with the
default settings. To adapt it to special requirements, please observe the notes in
chapter 7.1, ”speed-controlled operation”.

Set-value

Terminal

Parameter setting with

speed set-value

X1/8

C025 = -4-

Additional set-value

X1/6

C025 = -3-

External torque selection M

set

X1/1, 2

C025 = -1-

The speed set-value and the additional set-value are selected as bipolar values via
X1/8 or X1/6. The direction of rotation results from the sign of the linkage between
main and additional set-value and the selection made at X2/21 und X2/22.

Show/Hide Bookmarks

Advertising