3 rated data, 1 mains voltage 400v, Rated data – Lenze EDS4900U-REG User Manual

Page 32: Mains voltage 400v, Technical data

Advertising
background image

Technical Data

3-4

48XX/49XXSHB0399

3.3

Rated data

3.3.1

Mains voltage 400V

( Controllers 4902 to 4907 (4Q controllers)

Type

4902

4903

4904

4905

4906

4907

Order No.

EVD 4902-E EVD 4903-E EVD 4904-E EVD 4905-E EVD 4906-E EVD 4907-E

Output power

1)

P

el

[kW]

6.7

10.5

23.1

46.2

84

105

Mains voltage

V

mains

3

¼ 340...460 V~ á0%, 50...60Hz

Armature voltage

V

A

420V if V

mains

= 400V (1.05

¼V

mains

)

Rated armature current
(continuous operation)

I

Arated

[A]

16

25

55

110

200

250

Maximum current
(short-time operation)

I

Amax

[A]

29

45

90

150

240

300

Field voltage

2)

V

F

V

Fmax

= 0.875

¼V

L1

-

L3

Max. field current,
controlled

I

F

[A]

3.5

10

Power loss

3)

P

loss

[W]

60

108

185

288

577

650

Ambient temperature in
operation

T

amb

[

•C]

0...+ 45

0...+ 35

4)

Weight approx.

[kg]

9,2

13,1

13,8

18

22

23

( Controllers 4908 to 4913 (4Q controllers)

Type

4908

4909

4911

4912

4913

Order No.

EVD 4908-E

EVD 4909-E

EVD 4911-E

EVD 4912-E

EVD 4913

Output power

1)

P

el

[kW]

139

210

294

420

504

Mains voltage

V

mains

3

ô 340 ... 460 V~ á0%, 50...60Hz

Armature voltage

V

A

420 V if V

mains

= 400V (1.05

ôV

mains

)

Rated armature current
(continuous operation)

I

Arated

[A]

330

500

700

1000

1200

Maximum current (short-time
operation)

I

Amax

[A]

400

600

840

1200

1350

Field voltage

2)

V

F

V

Fmax

= 0,875

¼V

L1

-

L3

Max.field current, controlled

I

F

[A]

15

30

Power loss

3)

P

loss

[W]

840

1220

2100

2850

3400

Ambient temperature in
operation

T

amb

[

•C]

0...+ 35

4)

Weight approx.

[kg]

28

28

60

60

60

Show/Hide Bookmarks

Advertising