Installation – Lenze EDS4900U-REG User Manual

Page 66

Advertising
background image

Installation

4-28

48XX/49XXSHB0399

( Variant V013 with PROFIBUS interface module
The interface module type 2130IB connects Lenze controllers to the fast serial
communication system PROFIBUS. With PROFIBUS it is possible to parameterize
and control a controller via a host.

4900Str116

FIG 4-21

Front view 2130IB

Connection

Explanations

X12

RS485 bus
connection

9-pole SubD socket

X13-W30

Optical fibre
receiver

(only 2130IB, V002)

X13-W31

Optical fibre
sender

(only 2130IB, V002)

V1

2130IB supply

OFF:
Module is not supplied. Controller is switched off or connection is
interrupted(X4).
ON:
Module is supplied.

V2

Communicatio
n 2130IB

OFF:
No supply or 2130IB and controller not yet initialised.
ON:
Module 2130IB and basic unit are initialised but the PROFIBUS-DP
communication is still not working.
FAST BLINKING (4x per second):
PROFIBUS-DP communication with user data
SLOW BLINKING (1x per second):
PROFIBUS-DP communication initialised

If the interface module 2130IB is no longer supplied, the bus system will not stop
working. However, the connected controller cannot be addressed by the host.

If necessary, the control stage of the controller should be supplied separately (see
chapter 4.3.3).