Digital frequencycoupling, Configuration – Lenze EDS4900U-REG User Manual

Page 122

Advertising
background image

Configuration

7-31

48XX/49XXSHB0399

Code

Name

Possible settings

Lenze Selection

Info

C145*

¤ Input

selection:
Analog
signal

1

-1-

Input terminals X1/1, X1/2

-2-

Input terminals X1/3, X1/4

-3-

Input terminal X1/6

-4-

Input terminal X1/8

-5-

Digital frequency input X5

-6-

Digital frequency input X9

-7-

Resolver

-8-

Motor potentiometer output

-9-

Output process controller

-10-

Output arithmetic block 2 output 1

-11-

Fixed setpoint output

-12-

Output arithmetic block 2 output 2

-13-

Output dead band element output 1

-14-

Output dead band elemeent output 2

-15-

Output DT1 element output 1

-16-

Output DT1 element output 2

-17-

Output absolute value generator output 1

-18-

Output absolute value generator output 2

-19-

Output limiting element 1 output 1

-20-

Output limiting element 1 output 2

-21-

Output PT1 element output 1

-22-

Output PT1 element output 2

-23-

Output arithmetic block 3 output 1

-24-

Output arithmetic block 3 output 2

-25-

Output addition block 1 output 1

-26-

Output addition block 1 output 2

-27-

Output addition block 2 output 1

-28-

Output addition block 2 output 2

-29-

n

act

from C382

-30-

n

set

from C050

-31-

Deviation at n-controller (xw)

-32-

Deviation at process controller (xw)

-33-

Ramp function generator output

-34-

n-controller output

-35-

Square-wave generator

-36-

Deviation at angle controller

-37-

RFG output of process controller setpoint

-38-

RFG output of process controller evaluation

-39-

AIF process controller setpoint

-40-

Output limiting element 2 output 1

-41-

Output limiting element 2 output 2

-42-

Output comparator 1

-43-

Output comparator 2

The functions set under C146 can be
assigned to the input sources under
C145. Double assignment is not possible.
The function selected last is always
assigned to the input.
C007 = -5-, -6-, -9-, -20-:
The priority for these inputs can be
determined under C147.
Change of C005 (configuration):
The freely selected assignments are
overwritten with a basic assignement that
depends on the configuration.
Assignments set before must be repeated.