6 limitation elements, Freely assignable comparator, Configuration – Lenze EDS4900U-REG User Manual

Page 170

Advertising
background image

Configuration

7-79

48XX/49XXSHB0399

7.5.6

Limitation elements

Purpose

The controller provides two limitation elements. With these function blocks signals
can be limited to adjustable value ranges.

Parameter setting

4900Str062

C 1 4 6 / C 1 4 7

C 1 4 5 / C 1 4 6

C 6 3 2

C 1 4 5 / C 1 4 6

C 6 3 1

C 6 3 0

I n p u t

O u t p u t 1

O u t p u t 2

FIG 7-35

Limitation element 1

4900Str062

C 1 4 6 / C 1 4 7

C 1 4 5 / C 1 4 6

C 6 3 2

C 1 4 5 / C 1 4 6

C 6 3 1

C 6 3 0

I n p u t

O u t p u t 1

O u t p u t 2

FIG 7-36

Limitation element 2

1. Input

With the function ”freely assignable analog inputs” each input can be assigned to
a ”terminal signal” from the table in C145.

2. Outputs

With the function ”freely assignable analog inputs” the outputs can be assigned to
the targets listed under C146.

3. Function

The function is an override function. If the input signal exceeds the upper limit
(C630 or C635), the upper limit is effective. If the input signal falls below the lower
limit (C631 or 636), the lower limit is effective.

Code

Name

Possible settings

Code

Name

Lenze Selection

Info

C630*

LE 1 upper
limit

100 % -100.0 %

{0.1 %}

100.0 %

-200 %

{1 %}

+ 200 %

C630 must be higher than C631!

C631*

LE 1 lower
limit

-100

%

-100.0 %

{0.1 %}

100.0 %

-200 %

{1 %}

+ 200 %

C631 must be smaller than C630!

C632*

Input, LE 1

0 %

-100.0 %

{0.1 %}

100.0 %

-200 %

{1 %}

+ 200 %

Display parameter only

C635*

LE 2 upper
limit

100 % -100.0 %

{0.1 %}

100.0 %

-200 %

{1 %}

+ 200 %

C635 must be higher than C636!

C636*

LE 2 lower
limit

-100

%

-100.0 %

{0.1 %}

100.0 %

-200 %

{1 %}

+ 200 %

C636 must be smaller than C635!

C637*

Input, LE 2

0 %

-100.0 %

{0.1 %}

100.0 %

-200 %

{1 %}

+ 200 %

Display parameter only

Abbreviation: LE = Limitation element

Show/Hide Bookmarks

Advertising