Installation

4-35

48XX/49XXSHB0399

4900Str023

l

l

L

L 1

L 2

L 3

P E

2

3

6

7

8

9

1 0

1 1

1 2

1

5

1 3

4

FIG 4-25

Part of the CE-typical drive system with 4X11 ... 4X13 on a mounting plate

1

Connection mains fuse

2

Connection fan supply L1/N

3

RFI filter

4

Uncoated surface for screen connection

5

Metal plug-in casing connected to screen or Lenze system cable

6

Screened signal cables

7

Motor connection with screened cable for act. value encoder

8

Commutating choke

9

Line protection fuses for field supply

10

Mains choke field supply

11

PE connection

12

RFI filter

13

Uncoated, bare metal contact surfaces