5 feedback systems, Installation – Lenze EDS4900U-REG User Manual
Page 59
![background image](/manuals/566281/59/background.png)
Installation
4-21
48XX/49XXSHB0399
4.3.5
Feedback systems
Several feedback systems can be connected to the controller and configured:
( Armature voltage control
( DC tacho feedback
( Resolver feedback
( Encoder feedback
- Incremental encoder TTL
- Incremental encoder HTL
DC tacho feedback
Tacho signals are connected via term. 3/4 of terminal block X1. The controller
processes rated tacho voltages of 10...180V (chapter 4.3.5.1).
Resolver feedback (X7)
( 2-pole resolver (V = 10 V, f = 5 kHz)
( Connection to a 9-pole Sub D socket X7
- We recommend to use the pre-cut Lenze system cable
(see chapter 13.3).
( Resolver cable and resolver are monitored for wire breakage (fault message
”Sd2”)
+ REF
-REF
+ COS
-COS
+ SIN
-SIN
1
2
3
4
5
6
7
8
9
X7
lmax= 50 m
4900Str015
FIG 4-15
Resolver connection (9-pole Sub D socket)
Pin assignment of socket X7:
Pin
1
2
3
4
5
6
7
8
9
Signal
+ REF
-REF
GND
+ COS
-COS
+ SIN
-SIN
---
---
Cross section
0.5
0.14
Show/Hide Bookmarks