5 additional function blocks, 1 process controller, Control of the motor potentiometer – Lenze EDS4900U-REG User Manual

Page 158: Configuration

Advertising
background image

Configuration

7-67

48XX/49XXSHB0399

7.5

Additional function blocks

7.5.1

Process controller

Description

The process controller is designed as independent function block and is a PID
controller with a cycle time of 12 ms.

It can for instance be used as superimposed controller (dancer position control,
tension control, etc.).

4900Str053

S e t

A c t .

O u t p u t

E v a l u a t i o n

I - c o m p o n e n t

s w i t c h - o f f

D e a c t i v a t i o n

p r o c e s s c o n t r o l l e r

S u p p r e s s i o n

p r o c e s s c o n t r o l l e r

FIG 7-26

Process controller

Features

( P adaptation possible via an internal function (derived from set-value) or

external analog signal source; enable adaptation with C329 = -1-

( Ramp function generator in set-value channel
( Overlay of process controller output over ramp function generator
( Intregral action component to be switched-off via freely assignable digital

terminal (I component = 0)

( Deactivation of the process controller via freely assignable digitale terminal (I

component = 0, output = 0)

( Suppression of the process controller output via freely assignable digital

terminal (output = 0 after time C335)