8 serial interface rs232/485, Installation – Lenze EDS4900U-REG User Manual

Page 64

Advertising
background image

Installation

4-26

48XX/49XXSHB0399

4.3.8

Serial interface RS232/485

Danger!

The interface RS232C/RS485 is not isolated, i.e. an additional electrical isolation
(double basic insulation) to VDE 0106, part 1, (protection against electric shock)
and to VDE 0160 (reduction of interference) is required for host connection.

LECOM-A:

with 2 Lenze level converters 2101IB connected to the host or
another RS 232C electrical isolation.

LECOM-B:

with Lenze level converter 2101IB connected to the host

LECOM-LI:

no additional electrical isolation required

Ensure electrical isolation of the voltage supply!

The controllers can communicate with the host (PLC or PC) via the serial interface
LECOM1 or an operating keypad that works according to the LECOM protocol.

The LECOM1 interface (X6) processes the LECOM-A/B protocol. The
LECOM-A/B protocol is based on the standard ISO 1745 and can be used with
up to 90 controllers. It detects faults and avoids the transmission of faulty data.

Controllers to standard RS232C (LECOM-A) or RS485 (LECOM-B) can be
connected to the LECOM1 interface. The interface can be used for parameter
setting, monitoring, analysis and simple control tasks.

With the RS232C interface, it is possible to create point-to-point connections with
a cable length of up to 15 m. Most PCs or other hosts are equipped with this
interface.

For multiple drives and distances >15m, use the RS485 interface. With only 2 wires
it is possible to connect up to 31 controllers and communicate over a cable length
of max. 1,200 m.

Pin assignment of socket X6:

Pin

Name

Input/output

Explanation

1

+ VCC15

Output

Supply voltage + 15V / 50mA

2

RxD

Input

Receive data cable

RS232C

3

TxD

Output

Transmit data cable

RS232C

4

DTR

Output

Transmission control

RS232C

5

GND

Controller reference potential

6

DSR

Input

(not used)

RS232C

7

T/R (A)

Output/input

RS485

8

T/R (B)

Output/input

RS485

9

+ VCC5

Output

Supply voltage + 5V

The baud rate can be changed under C125 (1200/2400/4800/9600 baud).

Protocol: LECOM-A/B V2.0

Show/Hide Bookmarks

Advertising