Freely assignable digital outputs (fdo), Configuration – Lenze EDS4900U-REG User Manual

Page 107

Advertising
background image

Configuration

7-16

48XX/49XXSHB0399

Rating to detect I

Fmin

With the parameter I

Fmin

(C231), the speed setting range is limited so that operation

at impermissible speed is avoided.

The following diagram is based on the standard excitation characteristic. The value
really required for I

Fmin

(C231) is however dependent on the excitation

characteristic of the machine used. The following indications can therefore only
serve the orientation.

4900Str032

1 , 0

0 , 5

1 2 % 1 9 %

3 2 % 3 9 % 4 7 %

5 7 %

7 1 %

1 0 0 %

I F

F r

I

n r

m a x

n

FIG 7-5

Detection of the min. field current in relation to the speed ratio

Example:

n

rated

= 1500 rpm, n

max

= 3000 rpm, i.e. n

rated

/ n

max

= 0.5

The value to be set under C231 is to be calculated.

Result:

For this speed ratio, the diagram indicates approx.
32% for C231.

If necessary, adapt the gain and the integral action time of the field controller under
C077, C078 to different field time constants of the motors. Set C077 and C078
that the field current does not oscillate in field weakening operation.

( V

ab

limitation

The integrated field controller enables the speed adjustment by field current
weakening. The field current operation is automatically derived from the control
level of the armature current controller. With the armature voltage limitation, the
max. motor voltage is limited to static V

Amax

= 1.05

ô V

Arated

(C090) (short-term

overswinging of the armature voltage possible).